B059M Fully Automatic Penetrometer
B059M Fully Automatic Penetrometer
B059M Fully Automatic Penetrometer
B059M Fully Automatic Penetrometer
B059M Fully Automatic Penetrometer
B059M Fully Automatic Penetrometer
- Description:
B059M Fully Automatic Penetrometer
- Model:
B059M
- Manufacturer:
Italy Matest
Product Information
  • Description
  • Standard
  • Feature
  • Specification
  • Configuration
  • Software
Description

B059M 全自动沥青针入度仪 (SMARTIP)

SMARTIP is an automatic apparatus for the determination of the needle penetration value, avoiding any possible operator lack of concentrationand ensuring a reliable repeatability of the results. It is a smart instrument thanks to the technologies adopted, the integrated microprocessor control and the user-friendly interface.


The instrument automatically reaches the contact point before starting the test and the penetration result is measured thanks to a high performance contactless displacement transducer. SMARTIP can be implemented with the device for an automatic measurement of electricallyconductive samples (model B059M-01), in order to improve the material tested range. An ultra-bright LED lamp helps the operator in checkingthe touching point of the needle while a stepper motor controls the vertical movement to reach exactly the desired point without any manualmovement of the plunger. The needle probe is automatically released for each penetration thanks to an electromagnetic system and automatically blocked at the end of the test.


The plunger comes back at the initial position at the end of each test by a simple recall command in order to re-positioning the needle beforethe new measurement. 


A 7” touch screen display is included in the SMARTIP frame, easy to use. It shows in real time the penetration/time graph, the test temperatureand the average result according to the number of tests done. Unlimited results can be saved on USB device for preparing a laboratory reportand for further analysis.


SMARTIP is supplied complete with the accessories for determination of the needle penetration according to EN 1426, ASTM D5 and AASHTO T49standards, and USB flash drive for saving data. Thermostatically controlled water bath, chiller, temperature probe PT100, device for an automaticmeasurement of electrically conductive samples and mirror can be ordered separately as accessories. 

B059M 全自动沥青针入度仪 (SMARTIP)

B059M 全自动沥青针入度仪 (SMARTIP)

Standard

• EN 1426

• ASTM D5

• AASHTO T49

• ASTM D217

• BS 1377-2

• NF T66-004

• DIN 52210

• IP 49

• JIS K 2207

Feature

• Fully automatic test, simply pressing the STARTbutton: approach, touch point, penetration.

• Automatic identification of the needle contactpoint and needle positioning, avoiding any possibleoperator lack of concentration and ensuring areliable repeatability of the results.

• Electro-magnetic needle probe release to performthe test.

• Automatic zero at the contact before startingpenetration.

• Penetration measurement thanks to a high-techcontactless displacement transducer with 0.01 mmresolution, in a range of 0 - 50 mm.

• 7" touch screen display equipped with an userfriendly software and clear interface.

• Real time display of penetration/time curve, averageresult and test temperature.

Specification
DescriptionTechnical Specification
Measuring range0~50mm
Resolution0.01 mm
Screen display7”touch screen display
Test time5s(adjustable from 0 to 9999 s)
Programmable delay timefrom 0 to 999 s
Programmable reference positions for holder assembly
Test simultaneously displayedup to 10
ConnectionUSB port and LAN port for PC connection
Power supply110-230V 50-60Hz 1ph
Overall dimensions325 x 400 x 730mm
Weight approx25 Kg approx


Configuration
Accessories/Spare Parts

ACCESSORY

• B058:Thermostatically controlled water bath

• B058-01:WATER BATH DISH with incorporated thermostaticcoil, to be connected to the bath mod. B058.It keepsthe temperature of the bitumen sample directly on thepenetrometer, by avoiding to transfer it.Dimensions Ø 151x90 mm

• B058M:WATER CHILLER: 7.5 l capacity, with electronic temperature controller with ± 0.1 °C accuracy and fluid temperature range between 5 and 30°C. Suitable for chillingpenetrometer water baths or temperature controlled setting time tests

• B059M-11:TEMPERATURE PROBE, PT100: Measurement of thesample temperature in real time. It’s connected with themonitor in order to show the temperature during eachtest, to collect the data at the end of penetration and toinclude the temperature data in the final reading

• B057-08:THERMOMETER, IP 38C

• B057-06:PENETRATION NEEDLE conforming to EN 1426 andASTM D5, supplied with official UKAS certificate

• B057-07L:LONG NEEDLE hardened

• B057-03: GLASS TRANSFER DISH

• B057-09: STANDARD PENETRATION CONE conforming to ASTMD217 and EN 13880-2


SPARES for B059M

• V122-05:Sample cup 55x35 mm

• V122-06:Sample cup 70x45 mm

• B057-07:PENETRATION NEEDLE, individually verified

• B057-04N:50 g weight

• B057-05N:100 g weight

B059M 全自动沥青针入度仪 (SMARTIP)    B059M 全自动沥青针入度仪 (SMARTIP)